PRECISION OPTICS · SPECTROSCOPY · LASER TECHNOLOGY

See beyond.
Measure with confidence.

Optical measurement solutions engineered for demanding research, industrial analysis and advanced laser applications.

180–1100 nmSpectrometer coverage*
0.1 nmHigh-resolution option*
1064 nmQ-switched laser platform
*Depending on model and configuration. Refer to individual datasheets.
OPTICAL SYSTEMSPrecision at every wavelength.
ENGINEERED FORScientific ResearchIndustrial AnalysisLaser ApplicationsOEM Integration
PRODUCT PORTFOLIO

Tools for your
next discovery.

Explore our current range of spectrometer platforms and 1064 nm laser sources. Select a product to review key specifications and download its datasheet.

FEATURED PRODUCTS
TE-COOLED CCDOPTO-5020P spectrometer
HIGH SENSITIVITY · HIGH RESOLUTION

OPTO-5020P

TE-cooled back-thinned spectrometer designed for low-noise measurements and weak-light detection.

2048 pixels180–1100 nm*USB 2.0
ULTRA-HIGH RESOLUTIONAPTO 30-07 multi-channel spectrometer
ULTRA-WIDE RANGE · MULTI-CHANNEL

APTO 30-07

Five high-resolution optical spectrometers integrated into one platform for demanding spectral analysis.

4096 × 5 pixels0.1–0.16 nm200–1100 nm*
AIR-COOLEDOPTO-1064-D laser head
DIODE-PUMPED · Q-SWITCHED

OPTO-1064-D

Compact 1064 nm all-solid-state laser platform with selectable single-pulse energy configurations.

1–10 mJ<10 ns1–100 Hz
WATER-COOLEDOPTO-1064-H laser system
HIGH ENERGY · HIGH BEAM QUALITY

OPTO-1064-H

High-energy 1064 nm Q-switched laser system for scribing, cutting, laser processing and research.

10 mJ<5–10 ns*1–100 Hz

*Specifications are configuration-dependent. Please consult OPTOMAX for confirmation of the required wavelength range, resolution, slit width and operating conditions.

SPECTROMETER · 01

OPTO-5020P

High-sensitivity, TE-cooled back-thinned spectrometer

Built around a back-illuminated linear CCD and low-noise signal-processing electronics, the OPTO-5020P is designed for applications where weak optical signals and measurement stability matter.

  • TE-cooled back-illuminated linear CCD, 2048 effective pixels
  • Optical resolution: 0.2–3 nm, depending on range and slit
  • Signal-to-noise ratio: >900:1; dynamic range: 10,000:1
  • SMA905 fiber input or free-space optical input
  • USB 2.0 data interface; 5 V DC supply
Download full datasheet ↓
OPTO-5020P instrument
2048Effective pixels
10 ms–65 sIntegration time
5 V DCPower supply
1.6 kgWeight
APTO 30-07 spectrometer
4096 × 5Probe pixels
0.1–0.16 nmOptical resolution
200–1100 nmSpectral range*
12 V DCPower supply
SPECTROMETER · 02

APTO 30-07

Ultra-wide range, ultra-high resolution spectrometer

The APTO 30-07 integrates five high-resolution optical spectrometers, each using a high-sensitivity linear CMOS detector. It is designed for plasma emission, laser wavelength measurement and advanced spectral analysis.

  • Five integrated spectrometers; 4096 × 5 probe pixels
  • Optical resolution: 0.1–0.16 nm, depending on slit and range
  • 16-bit digital output; 1 ms–130 s integration time
  • SMA905 fiber input or free-space optical input
  • USB 2.0 interface; datasheet description also references UART output
Download full datasheet ↓
LASER SOURCES · 1064 NM

Power engineered
for precision.

Two Q-switched laser configurations for different pulse-energy, cooling and integration requirements.

01 / AIR-COOLEDOPTO-1064-D laser head

OPTO-1064-D

High-energy diode-pumped all-solid-state Q-switched laser.

Wavelength1064 ± 1 nm
Single-pulse energy1–5 / 5–10 mJ
Pulse duration<10 ns
Repetition rate1–100 Hz
CoolingAir cooled
Supply24 V DC / 18.8 A
Download datasheet ↓
02 / WATER-COOLEDOPTO-1064-H laser system

OPTO-1064-H

High-energy Q-switched laser with high beam quality and short pulse duration.

Wavelength1064 ± 1 nm
Single-pulse energy10 mJ
Pulse duration<5–10 ns*
Repetition rate1–100 Hz
CoolingWater cooled
Power supply110/220 VAC PSU
Download datasheet ↓

Laser safety: These are high-power Class IV laser products as indicated in the supplied datasheets. Operation requires appropriate laser safety controls, trained personnel and suitable protective measures. Confirm the final product classification and safety documentation with the manufacturer.

APPLICATION AREAS

Designed around
real-world measurement.

01Raman & optical spectroscopy

Weak fluorescence, reflectance, transmittance and absorbance measurements.

02LIBS & plasma analysis

Plasma emission spectroscopy and laser-induced breakdown spectroscopy systems.

03Laser research & processing

Laser wavelength measurement, scribing, cutting and scientific research.

04Industrial integration

OEM spectroscopy systems, process analysis and application-specific configurations.

O.
ABOUT OPTOMAX

Optical technology.
Practical innovation.

Changsha Optomax Instruments Co., Ltd. focuses on optical spectroscopy instruments and laser technology for scientific and industrial applications. We work with customers to identify suitable configurations and support product integration from evaluation to deployment.

Discuss your application ↗
START A CONVERSATION

Let's find the
right solution.

Tell us your wavelength range, resolution, pulse-energy or integration requirements. Our team will help you identify a suitable configuration.

This form opens your email application with the inquiry details. It does not submit data to a server.